Performance characteristics:
 
Innovative design of goniometer
Patented innovative steel belt drive system can provide stable rotary motion without return clearance to ensure high-precision angular positioning requirements;
Theta/2 theta two axes move independently, and cooperate with servo motor and circular grating to form a closed-loop system;
Permanent magnet AC servo motor provides the industry's top high-speed smooth motion;
The repeatability of circular grating angle measurement can reach 0.0002 degrees and the accuracy can reach 0.0006 degrees, which is enough to ensure excellent angle measurement performance;
 
Digital multichannel analyzer
12-bit, 80M/s analog-to-digital conversion sampling rate, is a high-resolution signal sampling system in the industry, which ensures the integrity of signal acquisition
Based on high-speed FPGA framework and reliable digital signal processing algorithm, the 4096-channel analysis system is sufficient to screen the correct X-ray signal from noise
Large dynamic range measurement effectively reduces the number of detector gain adjustment
 
X-ray tube and high pressure
Standard 4kW high power supply system supports high sensitivity trace detection and faster inspection speed
The beryllium window thickness of 50um/75um ensures ultra-high X-ray transmittance, which is especially suitable for low-energy X-rays to pass through
The voltage and current of high voltage power supply can reach 60kV and 160mA, and users can flexibly set voltage and current parameters according to actual needs
Dual-channel water cooling system, the conductivity is kept below 1uS, so as to prolong the working life of smooth pipe to the maximum extent. Others
More than 10 crystals can be supported, and specially optimized artificial multilayer crystals can be provided according to customer requirements to improve the detection ability of light elements
The thin window film of proportional flow gas counter can reach 0.3 um, which greatly improves the luminous flux of light elements
 
Others:
The temperature control stability of the spectrum chamber is within 0.05 C
The crystal, collimator and filter are all controlled by automatic switching
Software
Complete and rich software functions
32-bit software system, excellent operability and human-computer interaction interface
Mature empirical coefficient method combined with standard samples to provide accurate and reliable detection data
The basic parameter method can provide various analytical methods, and can be used for semi-quantitative and quantitative analysis without standard samples
The integrated SQLite database is used to save experimental data, which is convenient for data query and management