Technical parameters: -Z Large measurable sample size: φ 200 mm or 140 × 140mm Surface resistance test: -Test method: four-probe contact test -Test range: 1 m Ω/sq ~ 2 m Ω/sq -Test point: Center point only Resistivity test: -Test method: four-probe contact test (input thickness is required) -Test range: 10.0 μ Ω · cm ~ 200.0 K Ω · cm -Test point: Center point only Data processing software: -Use with personal computers -Connection method: USB connection -Data management: save, load, export -Data analysis: viewing, statistics... Product features: -Automatic contact unit -Manual or automatic selection of test range -Single and double measurement methods -The size of the sample table can be customized
|